Camac Module ES-7103 -- Predet Timer

This 6" wide module accepts a 1 Mhz bipolar experimental clock and repeats the clock at its output. It has a front panel thumb wheel switch to select one of 14 references time, INHIBIT, or EXTERNAL-IN. There are four sets of five digit 10 position thumbwheel switches, and four outputs corresponding to each set of thumbwheel switches. They are delayed time per 1, 10, or 100 uSec/unit (depending on the selection of 10K, 100K, 1Mhz ) with respect to the reference time. External reference time and the four basic reference times (main ring reset, start of ramp, beginning of flattop, and end of flattop) are available.

FRONT PANEL
Thumbwheel Switches

1)N1-Delay time with respect to reference time (R+N1)
2)N2-Delay time with respect to reference time (R+N2)
3)N3-Delay time with respect to reference time (R+N3)
4)N4-Delay time with respect to reference time (R+N4)
5) Ref. Time- Selects gaps 1 thru 14



     Lights

         1)   100usec     -  100 usec/unit is selected
         2)   10    usec  -  10 usec/unit is selected
         3)   1 usec      -  1 usec/unit is selected
         4)   R+N1       -  Flashes  with  pulse  from   N1   output
         5)   R+N2        -  Flashes  with  pulse   from N2   output
         6)   R+N3        -  Flashes  with  pulse  from  N3   output
         7)    R+N4      -  Flashes  with  pulse  from  N4   output
         8)   REF         -  Flashes  when selected reference time fires
         9)NIM-TTL        -  RED  for  NIM type, GREEN for TTL type

  Rotary    Knobs     Selects

         a)   100 usec - Switch setting 100 usec/unit
         b)   10   usec - Switch setting 10 usec/unit
         c)   1    usec - Switch setting 1 usec/unit

  Isolated BNC     (Transformer coupled)

         Clock    In   Input for bipolar experimental clock
                       (internally   terminated)    .
         Clock Out     Buffer bipolar clock output

  Lemo   Outputs  (Transformer coupled 5v usec into 50 ohm)

         1)     R+N1   -  Pulse  output  delayed  by   N1   setting   with
                          respect    to    reference.
         2)  R+N2      -  Pulse    output    delayed  by   N2   setting   with
                          respect    to    reference
         3)  R+N3      -  Pulse    output    delayed  by  N3  setting  with
                          respect    to    reference
         4)  R+N4      -  Pulse    output    delayed  by  N4   setting   with
                          respect    to    reference
         5)  T1        -  Main   Ring   reset   pulse

         6)  T2        -  Start of Main Ring ramp pulse

         7)  T5        -  Beginning of flattop pulse

         8)  T6        -  End   of   flattop   pulse

         9)  Ref    Out-  Selected reference output pulse

 Lemo     Input

         Ext.  In - For External Reference with Ref. time thumbwheel
                    set to EXT.

Up to a higher level directory  | |  For more information