MODEL 50C BRANCH TERMINATION UNIT

The Jorway Model 50C Branch Termination Unit is designed to be used in systems employing the standard Branch Highway and Type A or A-1 Crate Controllers. An integral cable assembly allows the unit to be easily connected to the Branch Highway without the need for additional cables. The Model 50C terminates and provides current sources for the sixty five (65) active branch lines. Addition- ally the two cable shield lines (BSC) are internally grounded. The Model 50C meets all of the applicable requirements or EUR4100e and EUR4600e.

SPECIFICATIONS


Terminating Impedence   100 ohms

Open Circuit Voltage   +4.lv

Short Circuit Current   40ma

Power Requirements   +6v @ 2600 ma max.

Mechanical    Double width CAMAC module
     with metal side shields.

Cable Length    1.5 feet

Up to a higher level directory  | |  For more information