Voltage range: 0-250VDC
|
Max current at Ambient of: |
|||
|---|---|---|---|
|
30'C |
40'C |
50'C |
60'C |
|
0.13 |
0.12 |
0.11 |
0.10 |
|
REGULATED VOLTAGE OUTPUT |
|
|
0. 01 percent plus 1. 0 millivolt for input variations from 105-132 or 132-105 volts AC |
|
0. 01 percent plus 1. 0 millivolt for load variations from no load to full load or full load to no load |
|
Remote Programming |
|
|
Nominal 200 ohms/volt output |
|
One-to-one voltage change |
|
Ripple and Noise |
500 microvolts (or 1 mv for LPD-425FM) rms; 1. 5 millivolts (or 3 mv for LPD-425FM) peak-to-peak with either positive or negative terminal grounded |
|
Temperature Coefficient |
Output change in voltage less than (0. 015% + 0. 5 mv) /'C |
|
DC OUTPUT |
Current regulated for line and load; automatic crossover with voltage limit |
|
Current range must be chosen to suit the appropriate maximum ambient temperature. Current ratings apply for entire voltage range. For maximum current range see Table II Minimum current 1% of 30' ambient rating in Table II or 5 ma., whichever is greater. |
|
For voltage range see Table I; voltage ratings apply for entire current range. |
|
REGULATED CURRENT OUTPUT; AUTOMATIC CROSSOVER |
|
|
Regulation (line) |
5 milliamperes for line variations from 105-132 or 132-105 volts AC |
|
Regulation (load) |
5 milliamperes for load voltage changes from 0 to max. or max. to 0 volts DC |
|
AC INPUT |
105-132 volts AC at 47-440 Hz. For input power see Table III. Ratings apply for 57-63 Hz; derate current 10% for 47-53 Hz input; for other input frequencies consult factory. |
|
Input Power* |
115 watts |
|
OVERLOAD PROTECTION |
|
|
Thermal |
Thermostat, resets automatically when over- temperature condition is eliminated |
|
Electrical |
|
|
Adjustable, automatic, electronic current- limiting circuit, settable to 105 percent of rated current; limits output current to preset limit for protection of load and power supply when external overloads and direct shorts occur |
|
Fuse, "SLO-BLO", 3AG; fuse F1 protects the AC input circuit. Overload of the supply does not cause fuse failure. Fuse F2 provides protection against internal circuit failure in conjunction with overvoltage protector option |
|
INPUT AND OUTPUT CONNECTIONS |
Heavy duty terminal block on rear of chassis with 5-foot, 3-wire detachable line cord for all models; five-way binding posts provide for additional positive (+), ground, and negative (-) DC output connections, on front panel of all models . |
|
OPERATING AMBIENT TEMPERATURE RANGE AND DUTY CYCLE |
Continuous duty from O'C to 60'C ambient with correspond- ing load current ratings for all mades of operation |
|
STORAGE TEMPERATURE |
-55 C to +85 C |
|
METERS |
Voltmeter and ammeter on all models. |
|
CONTROLS |
|
|
Coarse and fine voltage and current controls (single ten turn controls for models LPD-424AFM and LPD-425AFM) permit adjustment of DC output; located on front panel of all models |
|
Five-way binding posts on all models. |
|
Provision is made for remote sensing to eliminate effect of power output lead resistance on DC regulation. |
|
Power |
Panel mounted switch and indicator light for all units |