MODELS 150, 151, 152, 153, 156 and 157
* Nylon Glide Guides - quick insert, tab locking, nylon guide
rails.
* Enclosed Wiring.
* Provision for Slide Rack Mount, Rack Mount, or Bench Top
Operation.
* Six Models to choose from to match your requirements.
* Optional perforated steel top and bottom covers, and steel cover
for connectors.
GENERAL DESCRIPTION
The Mech-Tronics Nuclear 150 Series NIM Instrument Bins have been designed to provide you with a selection to meet your application needs - from an unwired bin for your own wiring or storage, through the wired bin with Class A Power Supply, line filter and routing connectors.
The Instrument Bins were designed to complement your instrumentation through ease of Module insertion and removal, totally enclosed wiring, and precise alignment.
Model 150 Instrument Bin: Shell only, no connectors, switch, test points or lights supplied.
Model 151 Instrument Bin: Wired with connectors. Includes lights, test points, (+/-24, +/-12, +/-6) switch, and twelve wired connector blocks. The connector blocks each contain ten pins that supply +/-24, +/-12, +/-6, 115VAC, "clean" and "dirty" ground.
Model 152 Instrument Bin: Consists of Model 151 and NIM Class A Power Supply.
Model 153 Instrument Bin: Consists of Model 152 with input power line filter.
Model 156 Instrument Bin: Consists of Model 151 with NIM Class A Power Supply with connectors on power supply for powering other bins or bringing +/-6v into 156 Instrument Bin.
Model 157 Instrument Bin: Consists of Model 156 with input power line filter.
POWER SUPPLY SPECIFICATIONS
The Class A terminology is that described in AEC TI D-20893.
150, 151, 152, 153, 156, 157 2
SPECIFICATIONS
Input Power
Voltage: 103-129/206-258 VAC, single phase.
Frequency: 45-65 Hz.
Output Power: 96 Watts
Voltage: +12.OOOVDC Current: 2.OADC
- 12.OOOVDC 2.OADC
+24.OOOVDC 1.OADC
-24.OOOVDC 1.0ADC
Voltage Adjustment: + 1%.
Regulation/Stability: After 60 minutes warm-up at constant ambient temperature, the output
voltages will not vary more than +/-.05% during any 24 hour period for
maximum line load changes.
Recovery Time: 50 Microseconds to + 0. 1 % of the output voltage 88% to 110% line change
or a 10%-100% load change.
Ripple: 3 millivolts (peak to peak) maximum.
Noise: 3 millivolts (peak to peak) maximum to 50 MHz.
Output Impedance: 0.3 ohm maximum to 100 KHz.
Overload Protection: Electronic protection for overloads above 120% of rated output current
(automatic recovery).
Ambient: O'C to +60'C (operating).
Temperature Coefficient: 0.01%/'C maximum.
Thermal Warning/Thermal Cutout: As per TI D 20893.
Power Cord: 3 wire line cord (6' long).
Ordering Information:
Ordering Stock No. Shipping Weight
000150 00 15 1/2 lbs.
000151-00 17 lbs.
000152-00 36 lbs.
000153-00 36 lbs.
000156-00 36 lbs.