MODEL 503 LINEARGATE/504DUAL LINEAR GATE

* Baseline Restored
* Feedthrough 0.01%
* Gain Stability 0.01%/deg C
* Integral Linearity 0.1%

GENERAL DESCRIPTION
The Mech-Tronics Nuclear Models 503 and 504 Linear Gates perform a pass or inhibit decision on linear input signals. Input signals are passed for pulse height analysis only upon indication, by the presence or absence of a logic pulse at the gate input, that some external constraint has been met. The Model 504 places two 503's side by side in a double width module.

Gate duration is selected by a calibrated front panel control over a 1 usec to 10 usec interval. A front panel switch selects normal or block mode. When in the block mode a positive gate input inhibits the passage of the linear signal, the absence of a gate pulse permits passage of the signal. In the normal mode a positive gate input is required for linear signal passage.

All input pulses are baseline restored, providing a useful count rate range to 20,000 counts per second. The linear gate acts as a unity gain amplifier with an integral linearity of 0.1% over its entire dynamic input range.

COMPATIBILITY
The Models 503 and 504 are fully compatible with the entire family of Mech-Tronics linear, logic and counting modules.

Specifications

Input

Linear Signal Input:

  • Amplitude:

0.1 to 10 volts; 12 volts maximum; positive monopolar or bipolar

  • Impedance:

1 K ohm constant a.c. coupled

Gate Input

  • Amplitude:

+2 volts to +20 volts

  • Width:

> 50 nsec.

  • Impedance:

3.3 K ohm d.c. coupled

Output

Amplitude:

To 1 0 volts linear, 1 2 volts saturated

Impedance:

Two isolated 93.1 ohm outputs; common source impedance less than 0.4 ohms,

Performance

Gain:

Unity

Pedestal:

Internally adjustable to less than 1 mv

Gain Stability:

0.01%/degC

Integral Linearity:

>0.1% from 0.2 volt to 10 volts

Feedthrough:

>0.01%

Useful Count Rate:

20,000 counts/sec.

Controls

Gate Width:

Front panel calibrated control continuously adjustable from 1 to 10 usec.

Gate Mode:

Front panel two position toggle switch selects NORMAL or BLOCK mode of operation.

Connectors

Input:

Front and rear BNC Type UG 1 094/U

Gate:

Front and rear BNC Type UG1094/U

Output:

Front and rear BNC Type UG1094/U

503

504

Power Requirements:

+24 volts @ 20 ma

+24 volts @ 40 ma

- 1 2 volts @ 30 ma

- 12 volts @ 60 ma

+1 2 volts@ 70 ma

+ 1 2 volts @ 140 ma

-24 volts @ 50 ma

- 24 volts @ 1 00 ma

Weight:

3 lbs.

7 lbs.

Size:

Single Width AEC Module per TI D-20893